High Pressure Pumps – M…-3 series
MAXIMATOR pumps M series are available as single or double acting with either a single, double or triple air drive head. For air drive pressures from 1 bar (14.5 psi) minimum to 10 bar (145 psi) maximum.
M…-3 pumps
- single acting
- triple air drive head
- Pressures to 4,000 bar (58,000 psi)
M…-3 pumps are single acting triple air drive head pumps. Compared with the single acting single stage M pumps they reach triple pressure at the same air drive pressure.
M…-3 pumps are available with polyurethane seals. They come standard with bottom inlet, side inlet is available as option.
Options for M series
- Seal material for oil use (standard pump): Order code: M37 – (L)
- Special seal material to handle special fluids: Order code: See fluid compatibility guide
- Side inlet for single acting versions: Order code: M37(L) – S / M37(L)VE – S
- Special inlet and outlet ports (i. e. NPT): M37 – NPT
- Air control unit for M series with filter pressure regulator, control pressure gauge and shut-off valve: Order code: M37 with C1
- To protect the pump against excessive outlet pressures, an air safety valve can be fitted to the air control unit: Order code: M37 with C1/SVair
(The outlet pressure has to be indicated.) - Other options available on request
Type | i *¹⁾ | Displ. Vol. ¹⁾ /cm³ | Displ. Vol. ¹⁾ /in³ | P max. (*) bar | P max. (*) psi | Flow cfm | Flow l/min |
---|---|---|---|---|---|---|---|
M111-3 | 1:391 | 1,00 | 0,06 | 2500 | 36250 | 0,01 | 0,24 |
M189-3 | 1:660 | 0,60 | 0,04 | 4000 | 58000 | 0,14 |
i = Pressure ratio
P. max = Discharge
1) Numerical